The LoFlo sensor is the ideal capnography solution for all your CO2 monitoring requirements. Respironics offers the LoFlo engine for internal integration into your monitoring system. The LoFlo sensor's small, lightweight package is designed to be shared. It is easily moved from room to room to connect to your device or during transport. Mount the sensor to a bed rail, IV pole, or leave as part of the system cabling.

Features:
  • Ideal for non-intubated patients
  • Proprietary sample cell protects internal NDIR components from contamination
  • Common connector allows easy exchange between mainstream and sidestream monitoring
  • Robust and long life pump reduces periodic maintenance
  • No calibration required
  • Unique accessories & supplies for all patients
    Sample Flow Rate: 50 mL/minute +/-10 mL/minute
      Principle of Operation: Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
        Initialization Time: Capnogram, displayed in less than 20 seconds, at an ambient temperature of 25°C, full specifications within 2 minutes
          CO2Measurement Range: 0 to 150 mmHg, 0 to 19.7%, 0 to 20 kPa
        CO2 Resolution: 0.1 mmHg 0 to 69 mmHg
          0.25 mmHg 70 to 150 mmHg
        CO2 Accuracy: 0 - 40 mmHg +/-2 mmHg
          41 - 70 mmHg +/-5% of reading
            71 - 100 mmHg +/-8% of reading
              101 - 150 mmHg +/-10% of reading
                Above 80 BPM +/-12% of reading
                CO2 Stability Short term drift: Drift over four hours shall not exceed 0.8 mmHg maximum
                  Long term drift: Accuracy specification will be maintained over a 120-hour period
                    CO2 Noise: RMS noise of the sensor is less than or equal to 0.25 mmHg at 5% CO2
                      Sampling Frequency: 100 Hz
                        Respiration Rate Range: 0 to 150 Breaths Per Minute (BPM)
                          Respiration Rate Accuracy: +/-1 breath
                            Compensations: (Supplied by Host) Barometric pressure: 400 mmHg to 800 mmHg Operator selectable O2, N2O, HE and agent compensation
                              Calibration: No routine user calibration required
                                Sample Cell/Filter:Proprietary single patient use sample cell and inline filter are integrated with the sample line which effectively eliminates contamination of the internal system
                                  Nasal Sampling Kits for Non-intubated Patients:Nasal CO2 or CO2 with O2 delivery (Adult,Pediatric,Infant-Neonatal) Nasal/Oral CO2 or CO2 with O2 delivery (Adult, Pediatric)
                                    Airway Adapter Kits for Intubated Patients: Adult/Pediatric with and without dehumidification tubing. Pediatric/Infant, low deadspace, with and without dehumidification tubing Taper meets ISO 5356-1
                                      Sample Kit Hours of Use: Nasal and Oral/Nasal Cannulas without nafion - up to 12 hours Nasal and Oral/Nasal Cannulas with nafion - up to 120 hours. Airway Adapter Kits without nafion - up to 12 hours. Airway Adapter Kits with nafion - up to 120 hours
                                        Sample Cell Detection:Insertion automatically turns sampling pump on. Removal automatically turns sampling pump off
                                          Flow Control: Via P measurement across a capillary tube
                                            Scavenging Port: Yes
                                              Voltage Requirements: 5.0 VDC +/-5%
                                                Power Rating: Rated input: Less than 1.3 Watts typical. Steady state less than 2.0 Watts maximum on power up (warm up)
                                                  Interconnection: Standard - Lemo Redel 8-pin plastic LoFlo and CAPNOSTAT are interchangeable with the host monitor Common connector allows easy exchange between mainstream and sidestream monitoring
                                                    Temperature and Humidity: Operating: 0° to 40°C, 10 to 90% RH, non-condensing. Storage: -40° to 70°C, <90% RH, non-condensing
                                                      Water Resistance: IPX4 . Splash-proof (When sample cell is inserted in sample cell receptacle)
                                                        Shock Impact: IEC TR 60721-4-7 Class 7M3 (designed to withstand environments subject to significant vibrations or high shock levels). EN60068-2-27 shock, EN60068-2-64 random vibration
                                                          Data Interface: RS232, bi-directional, 19200 baud, standard N-8-1
                                                            Data Output: CO2 gas concentration (mmHg), end-tidal CO2, inspired CO2, respiratory rate. Gas and barometric pressure compensated when supplied by host
                                                              Regulatory Designed to meet IEC 60601-1-2, EN55011 - CISPIR 11 Class B (Radiated and Conductive Emissions), IEC 61000-4-2 Electrostatic Discharge Immunity, IEC 61000-4-3 Radiated Immunity. Designed to comply with 93/42/EEC (MDD CE Marking), FDA Standards, ISO21647, and Medical Electrical Equipment performance requirements for the basic safety and essential performance of respiratory gas monitors