RespSense® WIDESCREEN™ Capnograph. The RespSense capnography monitor with widescreen touch-panel display features MedAir™ sidestream EtCO2 technology for both intubated and non-intubated patients in a wide range of clinical settings. Portable, accurate and cost-effective, RespSense is suitable for use with patients in hospitals, sleep labs, and homecare.
Discontinued CLICK HERE TO DOWNLOAD WAVEFORM CAPNOGRAPHY BROCHURE CLICK HERE TO DOWNLOAD PRODUCT LINKNONIN RESPSENSE IS A PROVEN PERFORMER FOR:
- ET-tube placement verifications
- Waveform trend monitoring
- Detecting breathing irregularities
- Gauging the efficacy of CPR
NONIN RESPSENSE PRODUCT HIGHLIGHTS:
- WIDESCREEN touch-panel display
- MedAir EtCO2 technology
- Numerical pulse rate and respiratory rate display
- Numerical EtCO2 display
- Capnograph display
- Backlit LCD display
- Audible and visual alarms
Includes: (3) Filters, (3) Adult CO2 Sampling Nasal Cannulas, (1) CO2 Sample Line, (1) Moisture Trap, (1) Straight T-Connector, (1) Power Supply, (1) Plug-US, and (1) RespSense Operator's Manual on CD-ROM
RespSense® Specifications
Respiration Range: 3 to 60 respirations/minute
Update Frequency: Once every breath (No Breath alarm after 25 seconds)
Respiration Accuracy:
3 to 50 respirations/min +/- 2
51 to 60 respirations/min +/- 3
EtCO2/CO2 Range: 0 to 9.9 kPa or 0 to 99 mmHg
EtCO2/CO2 Accuracy:
+/-0.2 kPa / +/-2 mmHg, +8% of reading
540 - 795 mmHg
(EtCO2/CO2 reading reaches its steady state accuracy 10 minutes after power up)
Update Frequency: Once every breath (No Breath alarm after 25 seconds)
Sampling Rate: 4 Hz (4 times per second)
Total System Response Time: 4 seconds (includes delay time and rise time)
Drift of Measurement: Within CO2 accuracy specifications for 6 hours of continuous monitoring
Measurement: Automatic barometric pressure compensation and CO2 temperature compensation
Presented concentration of CO2 and EtCO2 can be false, indicating a high presence of nitrous oxide and other interfering gases.
The table below shows the CO2 and EtCO2 concentration corrections. Only use agents listed in the table below.
Agent Concentration Correction of Presented CO2 to Real Concentration
50 - 70% N2O Presented CO2 x 0.75 = Actual CO2
30 - 50% N2O Presented CO2 x 0.85 = Actual CO2
0 - 30% N2O No correction
0 - 5% Isoflurane No correction
0 - 4% Halothane Presented CO2 x 0.98 = Actual CO2
System Specifications
Power Data:
Power Supply: 100 - 240 VAC 50 - 60 Hz
Power Consumption:
3.6 W with battery operation
9 W with power supply
Battery Data:
Type: Lithium Ion (Li-Ion) internal battery, non-field replaceable, rechargeable
Battery Capacity: Approximately 8 hours
Charging Time: Approximately 24 hours
Physical Data:
Dimensions: 200 x 135 x 50 mm (7.9 x 5.3 x 2 in.)
Weight: 800 grams (1.8 pounds)
Operation:
Working Temperature: 32°F to 104°F (0 to 40°C)
Humidity: 10% to 90% (non-condensing)
Atmospheric Pressure: 720 to 1060 hPa (540 - 795 mmHg)
Altitude: Up to 9,000 ft (2,740 m)
Storage:
Temperature: -40°F to 158°F (-40°C to 70°C)
Humidity: 10% to 90% (non-condensing)
Pump:
Pump Flow: 75 ml/min
Flow Accuracy: +/-15 ml/min
Alarms:
Sound Pressure Level: 65 dBa maximum at 1 m in front of monitor
Classification per IEC 60601-1 / CAN/CSA-C22.2 No. 601.1 / UL60601-1:
Type of Protection: Internally powered class II (with power supply)
Degree of Protection: Type BF-Applied Part
Mode of Operation: Continuous
Enclosure Degree of Ingress Protection: IPX2